Titus HVAC DESV-10 10" Digital VAV No Control
Description
The Titus DESV-10 is a 10-inch digital variable air volume (VAV) box that keeps different building sections at a consistent temperature and humidity level. It is a component of a larger HVAC system, a VAV system, that controls the quantity of conditioned air distributed to various zones through the use of dampers. Due to the absence of an internal control system, the DESV-10 can only function with an external controller, such as the Titus Digital Controller. By communicating with the DESV-10 and receiving a temperature setpoint for the selected zone, this controller accurately controls the airflow by altering the internal damper. As only the necessary amount of conditioned air is sent to each zone, this exact control promotes both energy economy and maximum comfort.
Dimensions:
- Weight: 35.8 lbs
| Manufacturer Name: Titus HVAC Product Number: DESV-10 OEM Part Number: DESV-10 Product Description: 10" Digital Vav, No Control Weight:28.82lbs/13072.52g |
Choose the best HVAC equipment parts and supplies from PartsHnC!
Same Day Shipping
Best Quality And Best Price
Wide Range of Inventory
Best Customer Service
Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or contact@partshnc.com
Step 1: Shut off HVAC system power and isolate duct airflow.
Step 2: Mount digital VAV in correct airflow direction using structural supports.
Step 3: Connect ductwork ensuring airtight seals and proper alignment.
Step 4: Install external controller wiring since unit has no built-in control system.
Step 5: Verify damper movement, restore power, and test airflow calibration for correct zone performance.
-
What maintenance is required for the Titus HVAC DESV-10 Digital VAV?
Inspect the VAV box, damper assembly, and airflow sensing components regularly for dust buildup, obstructions, or mechanical wear. Verify that the damper moves freely and that all electrical and control connections remain secure.
-
What are common issues with the Titus HVAC DESV-10 Digital VAV?
- Damper sticking or restricted movement due to dust buildup.
- Actuator failure causing improper airflow control.
- Sensor drift leading to inaccurate temperature or airflow readings.
- Communication errors with building automation system.
- Airflow imbalance affecting zone comfort.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More
We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More
This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More