555 Results

HVAC transducers convert pressure readings into electrical signals that help regulate system performance. Replacing faulty transducers ensures accurate monitoring, protects equipment, and improves overall HVAC efficiency.

555 Results
Setra SRCMR25WBA2H2S Pressure Transducer
10% OFF
$2,715.41 Price reduced from $3,014.11
Setra SRCMR25WBA2H2S Pressure Transducer
10% OFF
SKU: SRCMR25WBA2H2S | Brand:
$2,715.41 Price reduced from $3,014.11
Please contact us about this item
Veris Industries PX3PXX02 Dry Differential Pressure Sensor Panel No Display 0-10"WC
13% OFF
$160.27 Price reduced from $184.31
Veris Industries PX3PXX02 Dry Differential Pressure Sensor Panel No Display 0-10"WC
13% OFF
SKU: PX3PXX02 | Brand:
$160.27 Price reduced from $184.31
Setra 26412R5WD11T1C Pressure Transducer 0/2.5" WC ±1% Accuracy 4/20mA Output
10% OFF
$226.04 Price reduced from $250.91
Setra 26412R5WD11T1C Pressure Transducer 0/2.5" WC ±1% Accuracy 4/20mA Output
10% OFF
SKU: 26412R5WD11T1C | Brand:
$226.04 Price reduced from $250.91
Please contact us about this item
Setra 26410R5WB11T1C Pressure Transducer ±0.5" WC 1% Accuracy 4/20mA Output
10% OFF
$226.03 Price reduced from $250.89
Setra 26410R5WB11T1C Pressure Transducer ±0.5" WC 1% Accuracy 4/20mA Output
10% OFF
SKU: 26410R5WB11T1C | Brand:
$226.03 Price reduced from $250.89
Aaon V38410 Pressure Transducer W/O Cable 0-667 PSI
13% OFF
$90.58 Price reduced from $104.16
Aaon V38410 Pressure Transducer W/O Cable 0-667 PSI
13% OFF
SKU: V38410 | Brand:
$90.58 Price reduced from $104.16
Please contact us about this item
Siemens SEZ91.6 Transducer 0-20 VDC To 0-10 VDC
13% OFF
$117.19 Price reduced from $134.76
Siemens SEZ91.6 Transducer 0-20 VDC To 0-10 VDC
13% OFF
SKU: SEZ91.6 | Brand:
$117.19 Price reduced from $134.76
Please contact us about this item
MAMAC Systems PR-282-2-1-B-1-2-B Differential Pressure Transducer
10% OFF
$312.02 Price reduced from $346.34
MAMAC Systems PR-282-2-1-B-1-2-B Differential Pressure Transducer
10% OFF
SKU: PR-282-2-1-B-1-2-B | Brand:
$312.02 Price reduced from $346.34
Please contact us about this item
Carrier HK05YZ003 Pressure Transducer
10% OFF
$365.77 Price reduced from $406.01
Carrier HK05YZ003 Pressure Transducer
10% OFF
SKU: HK05YZ003 | Brand:
$365.77 Price reduced from $406.01
Please contact us about this item
Johnson Controls DPT2090C-250G Pressure Transducers Conduit 0-250 PSI 5-5.5 VDC
10% OFF
$253.07 Price reduced from $280.91
Johnson Controls DPT2090C-250G Pressure Transducers Conduit 0-250 PSI 5-5.5 VDC
10% OFF
SKU: DPT2090C-250G | Brand:
$253.07 Price reduced from $280.91
Please contact us about this item
Johnson Controls DPT2090C-500G Pressure Transducers Conduit 0-500 PSI 5-5.5 VDC
10% OFF
$253.07 Price reduced from $280.91
Johnson Controls DPT2090C-500G Pressure Transducers Conduit 0-500 PSI 5-5.5 VDC
10% OFF
SKU: DPT2090C-500G | Brand:
$253.07 Price reduced from $280.91
Please contact us about this item
Veris Industries H622-10 Split Core Current Transducer 0-10A 0-5 VDC
13% OFF
$60.59 Price reduced from $69.68
Veris Industries H622-10 Split Core Current Transducer 0-10A 0-5 VDC
13% OFF
SKU: H622-10 | Brand:
$60.59 Price reduced from $69.68
Grundfos 92506685 Pressure Transducer 0-120 PSI 4-20mA
10% OFF
$292.48 Price reduced from $324.66
Grundfos 92506685 Pressure Transducer 0-120 PSI 4-20mA
10% OFF
SKU: 92506685 | Brand:
$292.48 Price reduced from $324.66

HVAC Pressure & Differential Transducer Replacement Parts

HVAC transducers are sensing devices that measure pressure levels and convert them into electrical signals for system monitoring and control. These components play a critical role in maintaining balanced airflow, refrigerant pressure stability, and overall equipment efficiency in residential and commercial HVAC systems.

HVAC pressure transducers monitor system pressures for safe, stable operation. Refrigerant pressure transducers measure suction and discharge pressures to protect compressors. Duct pressure transducers track airflow in ventilation systems, while differential pressure transducers compare two points, used in filters, clean rooms, and airflow balancing..

When a transducer fails, the system may experience inaccurate readings, improper cycling, compressor strain, or reduced efficiency. Faulty pressure feedback can lead to poor temperature control and increased energy consumption. Replacing damaged HVAC transducers restores accurate data transmission and supports reliable system regulation.

PartsHnC offers high-quality HVAC transducers, including solid-core current transducers, wet-media differential transducers, and digitally controlled transducers, compatible with leading brands such as Johnson Controls, Veris Industries, and MAMAC Systems, with fast shipping available nationwide.

FAQs

How do I know if a pressure transducer is failing?

Check for erratic readings, no response, or system alarms indicating over/under pressure. Replacing or recalibrating the transducer restores accurate monitoring.

Can a differential pressure transducer protect filters and clean rooms?

Yes, it monitors pressure differences and signals when filters are clogged or when airflow is off-balance. Regular checks prevent system inefficiency and equipment damage.

How do I clean and maintain a duct transducer?

Turn off the system and gently wipe the sensor and connections with a soft cloth. Avoid liquids entering the sensor or damaging electronic components.

How do I install a solid-core current transducer?

Place the conductor through the core without disconnecting the wiring and secure the unit. Connect the output to your monitoring system per the manufacturer's instructions.

Can a pressure transducer handle multiple PSI ranges?

Yes, some models like 0–25/50/100 PSI or 0–500 PSI support multiple ranges.

Ensure proper wiring and output type (4–20 mA, 0–10 VDC) for compatibility.

How do I test a differential pressure transducer?

Apply a known pressure difference and measure output voltage or current. Compare with specifications; recalibrate if the readings are outside tolerance.