Carrier 48GS400192 Flame Sensor

SKU: 48GS400192 5-48GS400192 Brand: Availability:
In Stock
(0)

$14.32 Price reduced from $21.95
Save $7.63
You can earn 1,000 Reward Points for registration!


Have a Question? 866-773-0907

Specifications:

Attribute Details
Length 1.6 "
Width 4.9 "
Height 1.75 "
Weight 0.07lbs
Type Flame Sensor

Description

The Carrier 48GS400192 Flame sensor for gas furnaces. A safety feature that ensures that the flame in your furnace is recognized. This elongated sensor has a length of approximately 1.6 inches and a width and height of 4.9 and 1.75 inches respectively. It has a crucial function in providing safe and secure furnace operation. This one uses a detection technique such as rectification or ionization to detect the flame during the operation of the furnace. When the burner ignites, the flame produces a particular electrical signal.

Dimensions:

  • Weight: 2 lbs
Manufacturer Name: Carrier
Product Number: 48GS400192
OEM Part Number: 48GS400192
Product Description: Flame Sensor
Weight:0.07lbs/31.75g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or contact@partshnc.com

Step 1: Turn off power and gas supply to the unit for safety.

Step 2: Access the burner compartment and place the existing flame sensor.

Step 3: Remove the mounting screw and disconnect the sensor wire carefully.

Step 4: Place the new sensor in position and secure it firmly.

Step 5: Reconnect the wire and ensure the rod remains clean and properly aligned.

Step 6: Restore power and gas supply, then test burner ignition and flame detection.

  • What maintenance is required for the Carrier 48GS400192 Flame Sensor?

    Clean the sensor rod regularly to remove carbon buildup and oxidation that can interfere with flame detection. Inspect wiring connections for looseness or corrosion. Ensure proper alignment within the burner flame path for accurate signal reading and better system operation.

  • What are common issues with the Carrier 48GS400192 Flame Sensor?

    • Carbon buildup causing weak flame signal.
    • Intermittent ignition or shutdown faults.
    • Corroded or loose wiring connections.
    • Failure to detect flame presence.
    • Contaminated or misaligned sensor rod causing ignition lockout.

Customer Reviews

No reviews yet. Be the first to write one!

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More