Robertshaw KA-1119-96 Well Thermostat
Description
The Robertshaw KA-1119-96 Well Thermostats are a critical component in HVAC systems, particularly heating equipment, that regulates and maintains desired temperatures. The Robertshaw KA-1119-96 Well Thermostat is intended to be inserted into a well or mounting pocket within the heating equipment, allowing it to precisely measure the temperature of the surrounding environment. It is commonly used in boilers, furnaces, and water heaters to provide efficient and consistent heating performance. The Robertshaw KA-1119-96 Well Thermostat provides improved comfort, energy savings, and an extended equipment lifespan. Overall, this thermostat plays an important role in optimizing the operation of heating systems through its offerings.
Dimensions:
- Weight: 3 lbs
Thermal Actuation:
Converts a change in thermal condition into movement within the thermostat mechanism. The sensing assembly undergoes a physical response as the temperature at its designated location varies. This response is transmitted through the internal mechanism, producing movement that positions the thermostat's operating elements. The mechanical action occurs within the component before contact movement takes place.
Control Switching:
Changes the electrical connection within the associated control circuit. The thermostat's contact mechanism moves between its defined positions after the internal operating mechanism reaches its switching condition. This contact action establishes or interrupts the applicable electrical path, providing the corresponding circuit output to connected equipment functions.
Replacement Guidelines:
Replacement of the Robertshaw KA-1119-96 Well Thermostat is necessary when visible damage, deterioration, or other physical conditions affect the thermostat's intended temperature-control role. Inspect the well thermostat and related connection areas for conditions that could affect proper temperature control within the equipment. Replace the component when it can no longer maintain its intended temperature-control operation within the equipment assembly.
Common Failure Symptoms:
- Temperature control becomes inconsistent.
- The associated circuit does not change state as expected.
- Equipment operation remains active or inactive unexpectedly.
- Control responses become intermittent.
- Temperature-related operation becomes irregular.
Equipment Compatibility:
The Robertshaw KA-1119-96 Well Thermostat should be used only in equipment applications specifically documented for this model. Verify the equipment model number, existing component identification, and manufacturer's parts documentation before purchase.
Technical Specifications:
Brand: Robertshaw
Part Number: KA-1119-96
Product Type: Well Thermostat
Step1: Turn off electrical power at the breaker and shut off the gas supply.
Step2: Allow the system to cool; drain fluid from the well if required.
Step3: Remove the old thermostat and capillary bulb from the well.
Step4: Insert the new sensing bulb fully into the existing well.
Step5: Secure the mounting bracket firmly and tighten all screws.
Step6: Reconnect wiring per the diagram; ensure tight, insulated terminals.
Step7: Restore power, check for leaks, and test setpoint operation.
-
What maintenance is required for the Robertshaw KA-1119-96 Well Thermostat?
Regularly check the thermostat for dust and corrosion, ensuring the contacts are clean. Test its calibration to maintain accurate temperature control. Tighten mounting and wiring connections as needed. Always disconnect power before performing maintenance for safety.
-
What are common issues with the Robertshaw KA-1119-96 Well Thermostat?
- Inaccurate temperature readings.
- Failure to turn equipment on or off.
- Loose or corroded electrical connections.
- Mechanical sticking or sensor malfunction.
-
What makes the KA-1119-96 different from a standard room thermostat?
The KA-1119-96 senses temperature at a designated equipment location through its well-based sensing arrangement rather than monitoring general air temperature in an occupied space.
-
How does the KA-1119-96 respond when the sensed temperature changes?
Its sensing assembly responds to changing thermal conditions and initiates movement within the thermostat mechanism.
-
What happens inside the thermostat after a thermal change is detected?
The internal mechanism responds to the thermal change and moves toward its defined operating position.
-
How does the KA-1119-96 affect an electrical circuit?
Its contact mechanism changes position to establish or interrupt the applicable circuit path.
-
What role does the KA-1119-96 serve in an equipment control assembly?
The KA-1119-96 provides temperature-responsive control action that can influence the electrical operation of connected equipment functions.
Customer Reviews
Write a Review
-
Steady Control
Temperature stays steady, no rapid cycling on/off after replacement.
-
Precise Control
Easy to set up and adjust for specific heating ranges.
-
Safe Operation
Efficient, accurate temperature regulation in heating systems
-
Quiet Operation
Effective thermostat, enhances home comfort, highly recommended
-
Works Perfectly
Works great, maintains temperature without fluctuations
We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More
We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More
This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More