The Tecumseh K90-56 Overload Kit is an indispensable component utilized in HVAC systems to safeguard compressors against electrical overload situations. Designed specifically to work with Tecumseh compressors, this kit includes an overload relay along with other necessary installation components. The compressor motor's electrical current is constantly monitored by the overload relay in order for it to function. In order to shield the compressor from harm, the relay quickly cuts off the power supply if it notices any surges or excessive current. The K90-56 Overload Kit, whether used in air conditioners, refrigeration systems, or heat pumps, guarantees safe and dependable compressor performance. Its well-thought-out design and sturdy build increase system longevity and performance while lowering the chance of compressor failure and requiring less maintenance.
Dimensions:
- Weight: 2 lbs
| Manufacturer Name: Tecumseh Product Number: K90-56 OEM Part Number: K90-56 Product Description: An overload kit is an essential component designed to protect the HVAC system's compressor from electrical overloads and potential damage. The core feature of an overload kit is thermal protection. It includes a temperature-sensitive device that monitors the compressor's temperature. Many overload kits have an automatic reset function. Once the temperature returns to a safe range, the overload kit resets itself, allowing the compressor to resume normal operation. Some overload kits offer a manual reset option for added safety. This requires manual intervention by a technician to reset the overload, which can be useful for diagnosing and addressing potential issues. In the event of an overload or overheating, the Tecumseh Compressor K90-56 Overload Kit can disconnect the electrical power to the compressor. This action prevents further electrical damage to the system. The overload relay is the primary component of the kit and is responsible for monitoring the electrical current flowing through the compressor motor. It trips or opens the circuit when it detects excessive current, protecting the motor from damage. A run capacitor is included in the overload kit. The run capacitor stores and releases electrical energy to assist in the continuous operation of the compressor motor. The kit may come with a pre-wired harness or set of wires that connect the overload relay, start relay, and run capacitor to the compressor and the electrical supply. The Overload Kit For Tecumseh Part# K90-56 is an integral component in HVAC systems that offers vital protection to the compressor motor against electrical overload and overheating conditions. Key features of the Tecumseh Compressor K90-56 Overload Kit are:
|
Choose the best HVAC equipment parts and supplies from PartsHnC!
-
Same Day Shipping
-
Best Quality And Best Price
-
Wide Range of Inventory
-
Best Customer Service
Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or contact@partshnc.com
Step1: Turn off power to the compressor for safety.
Step2: Disconnect the compressor wiring and remove the old overload system.
Step3: Position the new overload kit onto the compressor terminals.
Step4: Reconnect all wires securely according to their original positions.
Step5: Ensure the kit is seated properly and not loose.
Step6: Restore power and test the compressor for proper operation.
Step7: Verify the system starts and runs without overheating or tripping.
-
Do overload kits require regular maintenance or calibration?
Overload kits are designed to function without regular maintenance or calibration. However, periodic visual inspections are advisable to ensure all components are in good condition.
-
Can I use an overload kit in conjunction with other protective devices, such as surge protectors, to enhance my HVAC system's safety?
Using additional protective devices like surge protectors is a good practice. They complement the overload kit by providing comprehensive protection against various electrical issues.
-
Can an overload kit help prevent short cycling of my HVAC compressor?
Overload kits primarily protect against electrical overload conditions. Short cycling is typically managed by other control components, such as thermostats and pressure switches.
-
What maintenance is required for the Tecumseh K90-56 Overload Kit?
Regularly inspect the overload kit for signs of corrosion, overheating, or physical damage. Ensure connections are secure and replace any worn components. Proper maintenance supports protect the compressor from electrical faults. Always disconnect power before servicing the kit.
-
What are common issues with the Tecumseh K90-56 Overload Kit?
- Compressor failing to start or run.
- Tripping due to overheating.
- Loose or corroded electrical connections.
- Intermittent operation or false trips.
Customer Reviews
Write a Review
-
Professional-Grade Protection
I run a small HVAC maintenance business, and I trust this overload kit for my clients' systems. It's a professional-grade product that I can rely on.
-
Saves Time and Money on Repairs
“This overload kit not only protects my HVAC system but also saves me from costly compressor repairs. It's a small investment for long-term savings.”
-
A Lifesaver for My HVAC System!
“I installed this overload kit in my HVAC system, and tripped once during a power surge, saving my compressor from potential damage.”
We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More
We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More
This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More